Průmyslové kompresory - ITS > Compressed air dryers > Zephyr HR Heatless Dessicant Dryers

Zephyr HR Heatless Dessicant Dryers

Since compressed air quality has a major effect on the final product, adsorption dryers are extensively used in applications wherein a particular emphasis is placed on extreme quality and the minimization of residual water vapour in compressed air. By applying this drying principle in combination with a molecular sieve, a pressure dew point ranging from -40°C to -70°C DPT can be achieved.

The regeneration process is based on the principle of utilizing produced compressed air to dry the saturated desiccant in a single container. Cold regeneration adsorption dryers consume approximately 10 to 15% of the produced compressed air to maintain their operation. This consumption can be further reduced down to 7% via DPT-based control.

Reliable design
Ceramic balls at the bottom of the adsorption tower ensure uniform air flow distribution. This helps protect the adsorption content of the dryer against uneven loading.

Dryers in this line are equipped with high-performance, heat-resistant low pressure drop pneumatic valves with inlet and outlet filtration and a long service life.

Energy saving
The container regeneration cycles are controlled via LDCS and DPOS (Load Dependent Control System, Dew Point Operating System), containing a microprocessor control system to constantly monitor desiccant saturation and switch the container drying cycle when necessary.

Customer requirement variability
A wide range of options, including RS485, Profibus, Modbus and Ethernet connectivity, are available at extra cost.

ModelCapacity at
TRB -40°C
m3/min
Power
consumption
kW
Maximum
pressure
bar(g)
Dimensions mm
(L×W×H)
Weight
kg
Pipe
connection
ZD-20HR2,00,210779x549x1788198DN25
ZD-30HR3,00,210839x549x1703325DN25
ZD-60HR6,00,2101060x618x2020510DN40
ZD-80HR8,00,2101060x618x2020520DN40
ZD-100HR10,00,2101200x738x1824585DN50
ZD-120HR12,00,2151200x738x1824600DN50
ZD-150HR15,00,2151200x733x2028680DN50
ZD-200HR20,00,2151500x914x1973870DN65
ZD-250HR25,00,2151530x962x2056975DN65
ZD-300HR30,00,2151630x1199x20191150DN80
ZD-350HR35,00,2151790x1207x20491275DN80
ZD-400HR40,00,2151830x1232x20591350DN80
ZD-500HR50,00,2152012x1293x22381600DN100
ZD-600HR60,00,2152150x1321x25182100DN100

Data applicable to the following conditions: Pressure dew point -40°C, pressure 7bar(g), Air FAD 20°C/1 bar(a), Ambient temperature 38°C, Inlet air temperature 35°C, Cooling water temperature 30°C. Applicable to pressure due points in compliance with ISO8573-1:2001.